Data as of: 2026-08-05 Administration DE EN
Plant Protection Product Search

« Indications · to the product

ELATUS ERA

Use number: 008406-00/05-009

Crops
cup plant
Pests
rust fungi (Uredinales)
Area of use
Outdoors
Field of activity
Fungicide
Application technique
spraying
Growth stage
31 – 69
Applications per crop
Applications per growing season
1
Type of authorisation
Permit (minor use)
authorised until
2028-03-31

Application rates

ConditionProduct rateWater rate
1 LH 100 – 600 LH

Pre-harvest intervals

CropPre-harvest intervalRemarksexcluded
cup plant The setting of a PHI is without any relevance.

Timing of application

Purpose of use

Restrictions

Code Text Crop Buffer zone
NW605-2 When applying the product on areas adjacent to surface waters - except only occasionally but including periodically water bearing surface waters - the product must be applied with equipment which is registered in the index of 'Loss Reducing Equipment' of 10 September 2013 (Federal Gazette AT 23.10.2013 B4) as amended. Depending on the drift reduction classes for the equipment stated below, the following buffer zones must be kept from surface waters. In addition to the minimum buffer zone from su
NG371.1200 To protect the groundwater, the maximum application rate of the active substance benzovindiflupyr per hectare resulting from the active substance content, the specified application rate of the product and the specified number of treatments as well as the maximum number of treatments for the crop or per calendar year must not be exceeded, even taking into account applications of other plant protection products containing this active substance on the same area.
NG372.1200 This application is only permitted if no products containing the active substance benzovindiflupyr have been used on the same area within the previous calendar year.
NT140 Application of the product with a water application rate of less than 150 l/ha has to be conduct-ed with a field sprayer that is listed with a drift reduction class of at least 50 % in the list of "loss-reducing devices" in the first announcement on the entry of tested device types in the descrip-tive list pursuant to Section 52 (2) of the Plant Protection Act of September 10, 2013 (BAnz AT 23.10.2013 B4), as amended. The conditions of use for application with a drift reduction of at least 50 %
NW606 The only case in which the product may be applied without loss reducing equipment is when at least the buffer zone stated below is kept from surface waters - except only occasionally but including periodically water bearing surface waters. Violations may be punished by fines of up to 50 000 Euro. 15 m
NW706 Between treated areas which have an incline of more than 2 % and surface waters - including periodically but excluding occasionally water-bearing surface waters- there must be a buffer zone under complete plant cover. The buffer zone's protective function must not be impaired by the use of implements. It must be at least 20 m wide. This buffer zone is not necessary if: -sufficient catching systems are available for the water and soil transported by run-off, which do not flow into surface water o